Venecia


General description
Applications and Validation
Example 1: ITER. Toroidal Field Coil
Eхample 2: ITER. Central Solenoid and Poloidal Field Coils
AutoCAD meshing
Structure of the code, modelling strategy, interface
NUMERICAL SOLUTION
Summary
MATHEMATICAL MODELS:
Helium flow modelling
Conductor modelling
Collector modelling
Valve modelling
Modelling of solids
Pump modelling
Coolant properties



MATHEMATICAL MODELS. Collector modelling

The mathematical model collector is intended for 0-D simulation of helium behaviour in a collector and used as a node element for connecting different channels and valves in series-parallel to one another. The laws of mass and energy conservation define the helium behaviour inside the collector. For the collector i the following equations are used: